Archived material Access restricted Article
Rantburg

Today's Front Page   View All of Tue 08/18/2026 View Mon 08/17/2026 View Sun 08/16/2026 View Sat 08/15/2026 View Fri 08/14/2026 View Thu 08/13/2026 View Wed 08/12/2026
1
2026-08-18 -Signs, Portents, and the Weather-
Lightning struck an oil storage facility in the US, setting two tanks on fire
Archived material is restricted to Rantburg regulars and members. If you need access email fred.pruitt=at=gmail.com with your nick to be added to the members list. There is no charge to join Rantburg as a member.
Posted by badanov 2026-08-18 00:00|| E-Mail|| Front Page|| [174 views ]  Top

1 See it: Lightning triggers massive tank explosion in Oklahoma

[AI]
lightning arrestors on oil storage tanks

**Lightning arrestors** on oil storage tanks are critical safety devices used to prevent fires and explosions caused by direct lightning strikes or induced voltage surges. While some experts argue that large steel tanks can dissipate charge naturally, industry standards and regulations (such as those in Ohio for urbanized areas) often mandate the installation of **lightning arrestors** or comprehensive protection systems for petroleum storage.

Protection strategies typically involve two main approaches:

* **Lightning Protection Systems (LPS):** Traditional systems use air terminals (lightning rods) to intercept strikes and ground the current, often requiring specific spacing (e.g., rods spaced no more than 5 meters apart) and low-resistance grounding (typically under 10 ohms).
* **Lightning Prevention Systems:** Advanced technologies like the **Dissipation Array System (DAS)** aim to prevent strikes entirely by reducing the local electric field below the threshold for streamer formation, while **Retractable Grounding Assemblies (RGA)** ensure low-impedance bonding between floating roofs and tank shells to prevent arcing.
* **Flame Arresters:** Often installed on tank vents and breather valves, these devices allow vapor pressure equalization while physically blocking flames from entering the tank if an ignition source is present.

Proper implementation requires **equipotential bonding** of all metallic components, including floating roofs and piping, to prevent dangerous potential differences that could lead to sparks.
Posted by Skidmark 2026-08-18 06:51||   2026-08-18 06:51|| Front Page Top

2 Oilfield Artillery fights fires.

https://aoghs.org/technology/oilfield-artillery-fights-fires/
Posted by Besoeker 2026-08-18 09:30||   2026-08-18 09:30|| Front Page Top

3 https://aoghs.org/technology/oilfield-artillery-fights-fires/
Posted by Skidmark 2026-08-18 12:10||   2026-08-18 12:10|| Front Page Top

23:19 trailing wife
23:17 trailing wife
22:51 Hellfish
22:33 swksvolFF
20:04  chris
19:43 Frank G
19:41 Frank G
19:34 SteveS
19:33 Chantry
19:29 Chantry
19:24 Procopius2k
18:18 NN2N1
18:18 Bobby
18:00 NN2N1
17:57 NN2N1
17:33 Grom the Reflective
17:17 Lord Garth
17:05 swksvolFF
16:47 Grom the Reflective
16:38 Grom the Reflective
16:09 Grom the Reflective
16:00 NoMoreBS
15:54 Chantry
15:46 Chantry
Merry-Go-Blog










Paypal:
Google
Search WWW Search rantburg.com